Dupree office of noise control california department of health services berkeley california 94704 introduction building codes.
Stc 50 concrete wall.
In general the stl of a concrete masonry wall increases with increasing frequency of the sound.
However the additional weight added complexity of construction and poor thermal insulation tend to limit masonry wall partitions as a viable sound isolation solution in many.
This catalog of sound rated wall and the purpose of the indexing system is.
Weigh at least 50 less than masonry walls allowing faster easier installation for more information see the following brochures.
Determining sound transmission class stc for concrete masonry.
Stc 0 18w 40 where w pounds per square foot psf this information is provided as a tool to help estimate.
Insulation will noticeably improve the stc rating of an assembly.
To view different wall assemblies click on each point below that may apply to your project.
These tests have indicated a direct relationship between wall weight and the resulting stc heavier concrete masonry walls have higher stc ratings.
Due to increased mass poured concrete and concrete blocks typically achieve higher stc values in the mid stc 40s to the mid stc 50s than equally thick framed walls.
Catalog of stc and iic ratings for wall and floor ceiling assemblies russell b.
Metal stud walls perform better than wood stud walls.
These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
Staggered or double stud walls are higher rated than single stud walls.
There are numerous other issues that need to be addressed to.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
The estimate could easily be off by as much as 4 db.
Sound transmission class stc provides an estimate of the acoustic performance of a wall in certain common airborne sound insulation applications the stc of a wall is determined by comparing sound transmission loss stl values at various frequencies to a standard contour stl is the decrease or attenuation in sound energy in db.
Stc ratings for wall floor and window materials and assemblies 3 appendix a stc ratings a 1 walls a 1 exterior a 1 interior a 9 wooden studs a 9 metal studs a 14 floors a 16 wood a 16 concrete a 21 windows a 24 doors a 27 exterior a 27 interior a 29 appendix b references b 1.